  data sheet 3-phase filters fn 258 book-style emc/rfi filter for inverters and power d rive systems industry standard emc solution for three-phase pds filtering slim space-saving book-style housing solid safety connector blocks or optional wire output connections excellent attenuation performance hv versions for up to 690 vac hvit versions for it distribution networks p/l versions with low leakage current technical specifications design corresponding to ul 1283, csa 22.2 no. 8 1986, iec/en 60939 flammability corresponding to ul 94 v-2 or better high potential test voltage p C> e 2650 vdc for 2 sec (480v filters) p C> p 3000 vdc for 2 sec (690v filters) p C> e 3100 vdc for 2 sec (690v filters) p C> p 2100 vdc for 2 sec (480v filters) information under the labels ul/csa: hv and hvit up to 600 vac maximum continuous operating voltage 3x 480/277 vac (fn 258, fn 258l, fn 258p) 3x 690/400 vac (fn 258hv, fn 258hvit) mtbf @ 50c/400v (mil-hb-217f) 220,000 hours operating frequency dc to 60hz overload capability 4x rated current at switch on, 1.5x rated current for 1 minute, once per hour protection category ip20 rated currents 7 to 250 a @ 50 c (480v filters) temperature range (operation and storage) -25 c to +100 c (25/100/21) approvals ul/csa: fn 258 up to 180 a (ex. -180-07) features and benefits fn 258 range of filters provides state-of- the-art emi attenuation based on an innovative multi-stage filter topology. they help to ensure compliance wit h class a or even class b limits the slim book-style shape allows a convenient and space-saving installation next to inverters and motor drives with 480 vac rating and filter modules from 7 to 250 a, fn 258 are ready for the most diverse applications worldwide fn 258 hv filters up to 130 a are designed for 690 vac distribution networks fn 258hvit filters up to 130 a meet the special requirements for the application in industrial 690 vac it distribution networks fn 258l and fn 258p filters help to fulfill tough requirements in respect of leakage current limitation and provide an excellent solution to overcome problems with nuisance tripping of sensitive earth leakage detectors typical applications three-phase variable speed drives and power drive systems (pds) it power distribution networks (fn 258hvit) applications comprising energy conversion devices (inverters, converters) process automation equipment three-phase power supplies and ups applications with low-leakage current requirements (fn 258l and fn 258p) typical electrical schematic emc/emi products schaffner group datasheets 2014 filter selection table filter* rated current typical drive leakage current *** power loss input output weight @ 50 c (40 c) power rating** @ 440 vac/50 hz @ 25 c/50 hz connections connections [a] [kw] [ma] [w] [kg] fn 258-7-.. 7 (7.7) 4 16.5 9 -29 -07 -29 1.0 fn 258-16-.. 16 (17.5) 7.5 18.3 20 -29 -07 -29 1.4 fn 258-30-.. 30 (33) 15 24.2 21 -33 -07 -33 1.7 fn 258-42-.. 42 (46) 22 25.8 30 -33 -07 -33 2.5 fn 258-55-.. 55 (60) 30 25.8 30 -34 -07 -34 2.9 fn 258-75-34 75 (82) 37 25.8 24 -34 -34 3.9 fn 258-100-35 100 (110) 55 25.8 51 -35 -35 5.5 fn 258-130-35 130 (143) 75 30.0 50 -35 -35 6.9 fn 258-180-.. 180 (197) 90 30.0 73 -40 -07 -40 11.0 fn 258-250-.. 250 (275) 132 30.0 79 -40 -07 -40 12.0 fn 258hv-7-29 7 (7.7) 5.5 13.0 9 -29 -29 1.0 fn 258hv-16-29 16 (17.5) 11 19.0 20 -29 -29 1.5 fn 258hv-30-33 30 (33) 22 19.0 21 -33 -33 1.8 fn 258hv-42-33 42 (46) 30 21.6 30 -33 -33 2.6 fn 258hv-55-34 55 (60) 45 21.6 30 -34 -34 3.0 fn 258hv-75-34 75 (82) 55 21.6 24 -34 -34 4.3 fn 258hv-100-35 100 (110) 90 21.6 51 -35 -35 5.6 fn 258hv-130-35 130 (143) 110 25.0 50 -35 -35 7.1 fn 258hvit-7-29 7 (7.7) 5.5 13.0 9 -29 -29 1.0 fn 258hvit-16-29 16 (17.5) 11 19.0 20 -29 -29 1.5 fn 258hvit-30-33 30 (33) 22 19.0 21 -33 -33 1.8 fn 258hvit-42-33 42 (46) 30 21.6 30 -33 -33 2.6 fn 258hvit-55-34 55 (60) 45 21.6 30 -34 -34 3.0 fn 258hvit-75-34 75 (82) 55 21.6 24 -34 -34 4.3 fn 258hvit-100-35 100 (110) 90 21.6 51 -35 -35 5.6 fn 258hvit-130-35 130 (143) 110 25.0 50 -35 -35 7.1 fn 258l-7-.. 7 (7.7) 4 0.8 9 -29 -07 -29 1.0 fn 258l-16-.. 16 (17.5) 7.5 0.8 20 -29 -07 -29 1.4 fn 258l-30-.. 30 (33) 15 0.8 21 -33 -07 -33 1.7 fn 258l-42-.. 42 (46) 22 0.7 30 -33 -07 -33 2.5 fn 258l-55-.. 55 (60) 30 0.7 30 -34 -07 -34 2.9 fn 258l-75-34 75 (82) 37 0.7 24 -34 -34 3.9 fn 258l-100-35 100 (110) 55 0.7 51 -35 -35 5.5 fn 258l-130-35 130 (143) 75 0.7 50 -35 -35 6.9 fn 258l-180-.. 180 (197) 90 0.7 73 -40 -07 -40 11.0 fn 258l-250-07 250 (275) 132 0.7 79 -40 -07 12.0 fn 258p-7-.. 7 (7.7) 4 3.3 9 -29 -07 -29 1.0 fn 258p-16-.. 16 (17.5) 7.5 3.3 20 -29 -07 -29 1.4 fn 258p-30-.. 30 (33) 15 3.3 21 -33 -07 -33 1.7 fn 258p-42-.. 42 (46) 22 3.5 30 -33 -07 -33 2.5 fn 258p-55-.. 55 (60) 30 3.5 30 -34 -07 -34 2.9 fn 258p-75-34 75 (82) 37 3.5 24 -34 -34 3.9 fn 258p-100-35 100 (110) 55 3.5 51 -35 -35 5.5 fn 258p-130-35 130 (143) 75 3.5 50 -35 -35 6.9 fn 258p-180-.. 180 (197) 90 3.5 73 -40 -07 -40 11.0 fn 258p-250-07 250 (275) 132 3.6 79 -40 -07 12.0 * ** to compile a complete part number, please replace t he -.. with the required output connection style. ** * calculated at rated current, 440 vac (fn 258) / 690 vac (fn 258 hv) and cos phi = 0.8. the exact value depends upon the efficiency of the drive, the moto r and the entire *** application. ***maximum leakage under normal operating condition s (fn 258 at 440 v, fn 258 hv at 690 v). note: if t wo phases are interrupted, worst case leakage could reach 5.7 times *** higher levels. emc/emi products schaffner group datasheets 2014 typical filter attenuation per cispr 17; a = 50 /50 sym; b = 50 /50 asym ; c = 0.1 /100 sym; d = 100 /0.1 sym 7 to 30 a types 42 to 100 a types 130 a types 180 and 250 a types note: typical attenuation performance of fn 258 sta ndard filters. the behavior of fn 258 hv, fn 258hvi t, fn 258p and fn 258l may be slightly different. mechanical data 7 to 55 a types (-07) 7 to 130 a types (-29, -33, -34, -35) 180 and 250 a types (-07) 180 and 250 a types (-40) note: in favour of a better readability, connectors and earth studs are not shown in the horizontal pr ojection. emc/emi products schaffner group datasheets 2014 dimensions 7 a 16 a 30 a 42 a 55 a 75 a 100 a 130 a 180 a 250 a a 255 305 335 329 329 329 379 439 438 478 b 50 55 60 70 80 80 90 110 110 110 c 126 142 150 185 185 220 220 240 240 240 d 225 275 305 300 300 300 350 400 400 440 e 240 290 320 314 314 314 364 414 413 453 f 25 30 35 45 55 55 65 80 80 80 g 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 h 1 1 1 1.5 1.5 1.5 1.5 3 4 4 i 10.9 10.9 25 25 39 39 45 45 51 51 j m5 m5 m5 m6 m6 m6 m10 m10 m10 m10 k 25 27.5 30 35 40 40 45 55 55 55 l 85 100 110 130 105 140 130 140 110 110 x* awg 16 awg 14 awg 10 awg 8 awg 6 50 mm 2 70 mm 2 y* 300 10 300 10 400 10 500 10 500 10 500 10 500 10 z* 9 9 9 12 12 15 15 * filters with output wire connections (-07) only. all dimensions in mm; 1 inch = 25.4 mm tolerances according: iso 2768-m / en 22768-m filter input/output connector cross sections -29 -33 -34 -35 -40 solid wire 6 mm 2 16 mm 2 35 mm 2 50 mm 2 95 mm 2 flex wire 4 mm 2 10 mm 2 25 mm 2 50 mm 2 95 mm 2 awg type wire awg 10 awg 6 awg 2 awg 1/0 awg 4/0 recommended torque 0.6-0.8 nm 1.5-1.8 nm 4.0-4.5 nm 7-8 nm 17-20 nm please visit www.schaffner.com to find more details on filter co nnectors.
2 data sheet 3-phase filters fn 258 book-style emc/rfi filter for inverters and power d rive systems industry standard emc solution for three-phase pds filtering slim space-saving book-style housing solid safety connector blocks or optional wire output connections excellent attenuation performance hv versions for up to 690 vac hvit versions for it distribution networks p/l versions with low leakage current technical specifications design corresponding to ul 1283, csa 22.2 no. 8 1986, iec/en 60939 flammability corresponding to ul 94 v-2 or better high potential test voltage p C> e 2650 vdc for 2 sec (480v filters) p C> p 3000 vdc for 2 sec (690v filters) p C> e 3100 vdc for 2 sec (690v filters) p C> p 2100 vdc for 2 sec (480v filters) information under the labels ul/csa: hv and hvit up to 600 vac maximum continuous operating voltage 3x 480/277 vac (fn 258, fn 258l, fn 258p) 3x 690/400 vac (fn 258hv, fn 258hvit) mtbf @ 50c/400v (mil-hb-217f) 220,000 hours operating frequency dc to 60hz overload capability 4x rated current at switch on, 1.5x rated current for 1 minute, once per hour protection category ip20 rated currents 7 to 250 a @ 50 c (480v filters) temperature range (operation and storage) -25 c to +100 c (25/100/21) approvals ul/csa: fn 258 up to 180 a (ex. -180-07) features and benefits fn 258 range of filters provides state-of- the-art emi attenuation based on an innovative multi-stage filter topology. they help to ensure compliance wit h class a or even class b limits the slim book-style shape allows a convenient and space-saving installation next to inverters and motor drives with 480 vac rating and filter modules from 7 to 250 a, fn 258 are ready for the most diverse applications worldwide fn 258 hv filters up to 130 a are designed for 690 vac distribution networks fn 258hvit filters up to 130 a meet the special requirements for the application in industrial 690 vac it distribution networks fn 258l and fn 258p filters help to fulfill tough requirements in respect of leakage current limitation and provide an excellent solution to overcome problems with nuisance tripping of sensitive earth leakage detectors typical applications three-phase variable speed drives and power drive systems (pds) it power distribution networks (fn 258hvit) applications comprising energy conversion devices (inverters, converters) process automation equipment three-phase power supplies and ups applications with low-leakage current requirements (fn 258l and fn 258p) typical electrical schematic emc/emi products schaffner group datasheets 2014 filter selection table filter* rated current typical drive leakage current *** power loss input output weight @ 50 c (40 c) power rating** @ 440 vac/50 hz @ 25 c/50 hz connections connections [a] [kw] [ma] [w] [kg] fn 258-7-.. 7 (7.7) 4 16.5 9 -29 -07 -29 1.0 fn 258-16-.. 16 (17.5) 7.5 18.3 20 -29 -07 -29 1.4 fn 258-30-.. 30 (33) 15 24.2 21 -33 -07 -33 1.7 fn 258-42-.. 42 (46) 22 25.8 30 -33 -07 -33 2.5 fn 258-55-.. 55 (60) 30 25.8 30 -34 -07 -34 2.9 fn 258-75-34 75 (82) 37 25.8 24 -34 -34 3.9 fn 258-100-35 100 (110) 55 25.8 51 -35 -35 5.5 fn 258-130-35 130 (143) 75 30.0 50 -35 -35 6.9 fn 258-180-.. 180 (197) 90 30.0 73 -40 -07 -40 11.0 fn 258-250-.. 250 (275) 132 30.0 79 -40 -07 -40 12.0 fn 258hv-7-29 7 (7.7) 5.5 13.0 9 -29 -29 1.0 fn 258hv-16-29 16 (17.5) 11 19.0 20 -29 -29 1.5 fn 258hv-30-33 30 (33) 22 19.0 21 -33 -33 1.8 fn 258hv-42-33 42 (46) 30 21.6 30 -33 -33 2.6 fn 258hv-55-34 55 (60) 45 21.6 30 -34 -34 3.0 fn 258hv-75-34 75 (82) 55 21.6 24 -34 -34 4.3 fn 258hv-100-35 100 (110) 90 21.6 51 -35 -35 5.6 fn 258hv-130-35 130 (143) 110 25.0 50 -35 -35 7.1 fn 258hvit-7-29 7 (7.7) 5.5 13.0 9 -29 -29 1.0 fn 258hvit-16-29 16 (17.5) 11 19.0 20 -29 -29 1.5 fn 258hvit-30-33 30 (33) 22 19.0 21 -33 -33 1.8 fn 258hvit-42-33 42 (46) 30 21.6 30 -33 -33 2.6 fn 258hvit-55-34 55 (60) 45 21.6 30 -34 -34 3.0 fn 258hvit-75-34 75 (82) 55 21.6 24 -34 -34 4.3 fn 258hvit-100-35 100 (110) 90 21.6 51 -35 -35 5.6 fn 258hvit-130-35 130 (143) 110 25.0 50 -35 -35 7.1 fn 258l-7-.. 7 (7.7) 4 0.8 9 -29 -07 -29 1.0 fn 258l-16-.. 16 (17.5) 7.5 0.8 20 -29 -07 -29 1.4 fn 258l-30-.. 30 (33) 15 0.8 21 -33 -07 -33 1.7 fn 258l-42-.. 42 (46) 22 0.7 30 -33 -07 -33 2.5 fn 258l-55-.. 55 (60) 30 0.7 30 -34 -07 -34 2.9 fn 258l-75-34 75 (82) 37 0.7 24 -34 -34 3.9 fn 258l-100-35 100 (110) 55 0.7 51 -35 -35 5.5 fn 258l-130-35 130 (143) 75 0.7 50 -35 -35 6.9 fn 258l-180-.. 180 (197) 90 0.7 73 -40 -07 -40 11.0 fn 258l-250-07 250 (275) 132 0.7 79 -40 -07 12.0 fn 258p-7-.. 7 (7.7) 4 3.3 9 -29 -07 -29 1.0 fn 258p-16-.. 16 (17.5) 7.5 3.3 20 -29 -07 -29 1.4 fn 258p-30-.. 30 (33) 15 3.3 21 -33 -07 -33 1.7 fn 258p-42-.. 42 (46) 22 3.5 30 -33 -07 -33 2.5 fn 258p-55-.. 55 (60) 30 3.5 30 -34 -07 -34 2.9 fn 258p-75-34 75 (82) 37 3.5 24 -34 -34 3.9 fn 258p-100-35 100 (110) 55 3.5 51 -35 -35 5.5 fn 258p-130-35 130 (143) 75 3.5 50 -35 -35 6.9 fn 258p-180-.. 180 (197) 90 3.5 73 -40 -07 -40 11.0 fn 258p-250-07 250 (275) 132 3.6 79 -40 -07 12.0 * ** to compile a complete part number, please replace t he -.. with the required output connection style. ** * calculated at rated current, 440 vac (fn 258) / 690 vac (fn 258 hv) and cos phi = 0.8. the exact value depends upon the efficiency of the drive, the moto r and the entire *** application. ***maximum leakage under normal operating condition s (fn 258 at 440 v, fn 258 hv at 690 v). note: if t wo phases are interrupted, worst case leakage could reach 5.7 times *** higher levels. emc/emi products schaffner group datasheets 2014 typical filter attenuation per cispr 17; a = 50 /50 sym; b = 50 /50 asym ; c = 0.1 /100 sym; d = 100 /0.1 sym 7 to 30 a types 42 to 100 a types 130 a types 180 and 250 a types note: typical attenuation performance of fn 258 sta ndard filters. the behavior of fn 258 hv, fn 258hvi t, fn 258p and fn 258l may be slightly different. mechanical data 7 to 55 a types (-07) 7 to 130 a types (-29, -33, -34, -35) 180 and 250 a types (-07) 180 and 250 a types (-40) note: in favour of a better readability, connectors and earth studs are not shown in the horizontal pr ojection. emc/emi products schaffner group datasheets 2014 dimensions 7 a 16 a 30 a 42 a 55 a 75 a 100 a 130 a 180 a 250 a a 255 305 335 329 329 329 379 439 438 478 b 50 55 60 70 80 80 90 110 110 110 c 126 142 150 185 185 220 220 240 240 240 d 225 275 305 300 300 300 350 400 400 440 e 240 290 320 314 314 314 364 414 413 453 f 25 30 35 45 55 55 65 80 80 80 g 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 h 1 1 1 1.5 1.5 1.5 1.5 3 4 4 i 10.9 10.9 25 25 39 39 45 45 51 51 j m5 m5 m5 m6 m6 m6 m10 m10 m10 m10 k 25 27.5 30 35 40 40 45 55 55 55 l 85 100 110 130 105 140 130 140 110 110 x* awg 16 awg 14 awg 10 awg 8 awg 6 50 mm 2 70 mm 2 y* 300 10 300 10 400 10 500 10 500 10 500 10 500 10 z* 9 9 9 12 12 15 15 * filters with output wire connections (-07) only. all dimensions in mm; 1 inch = 25.4 mm tolerances according: iso 2768-m / en 22768-m filter input/output connector cross sections -29 -33 -34 -35 -40 solid wire 6 mm 2 16 mm 2 35 mm 2 50 mm 2 95 mm 2 flex wire 4 mm 2 10 mm 2 25 mm 2 50 mm 2 95 mm 2 awg type wire awg 10 awg 6 awg 2 awg 1/0 awg 4/0 recommended torque 0.6-0.8 nm 1.5-1.8 nm 4.0-4.5 nm 7-8 nm 17-20 nm please visit www.schaffner.com to find more details on filter co nnectors.
3 data sheet 3-phase filters fn 258 book-style emc/rfi filter for inverters and power d rive systems industry standard emc solution for three-phase pds filtering slim space-saving book-style housing solid safety connector blocks or optional wire output connections excellent attenuation performance hv versions for up to 690 vac hvit versions for it distribution networks p/l versions with low leakage current technical specifications design corresponding to ul 1283, csa 22.2 no. 8 1986, iec/en 60939 flammability corresponding to ul 94 v-2 or better high potential test voltage p C> e 2650 vdc for 2 sec (480v filters) p C> p 3000 vdc for 2 sec (690v filters) p C> e 3100 vdc for 2 sec (690v filters) p C> p 2100 vdc for 2 sec (480v filters) information under the labels ul/csa: hv and hvit up to 600 vac maximum continuous operating voltage 3x 480/277 vac (fn 258, fn 258l, fn 258p) 3x 690/400 vac (fn 258hv, fn 258hvit) mtbf @ 50c/400v (mil-hb-217f) 220,000 hours operating frequency dc to 60hz overload capability 4x rated current at switch on, 1.5x rated current for 1 minute, once per hour protection category ip20 rated currents 7 to 250 a @ 50 c (480v filters) temperature range (operation and storage) -25 c to +100 c (25/100/21) approvals ul/csa: fn 258 up to 180 a (ex. -180-07) features and benefits fn 258 range of filters provides state-of- the-art emi attenuation based on an innovative multi-stage filter topology. they help to ensure compliance wit h class a or even class b limits the slim book-style shape allows a convenient and space-saving installation next to inverters and motor drives with 480 vac rating and filter modules from 7 to 250 a, fn 258 are ready for the most diverse applications worldwide fn 258 hv filters up to 130 a are designed for 690 vac distribution networks fn 258hvit filters up to 130 a meet the special requirements for the application in industrial 690 vac it distribution networks fn 258l and fn 258p filters help to fulfill tough requirements in respect of leakage current limitation and provide an excellent solution to overcome problems with nuisance tripping of sensitive earth leakage detectors typical applications three-phase variable speed drives and power drive systems (pds) it power distribution networks (fn 258hvit) applications comprising energy conversion devices (inverters, converters) process automation equipment three-phase power supplies and ups applications with low-leakage current requirements (fn 258l and fn 258p) typical electrical schematic emc/emi products schaffner group datasheets 2014 filter selection table filter* rated current typical drive leakage current *** power loss input output weight @ 50 c (40 c) power rating** @ 440 vac/50 hz @ 25 c/50 hz connections connections [a] [kw] [ma] [w] [kg] fn 258-7-.. 7 (7.7) 4 16.5 9 -29 -07 -29 1.0 fn 258-16-.. 16 (17.5) 7.5 18.3 20 -29 -07 -29 1.4 fn 258-30-.. 30 (33) 15 24.2 21 -33 -07 -33 1.7 fn 258-42-.. 42 (46) 22 25.8 30 -33 -07 -33 2.5 fn 258-55-.. 55 (60) 30 25.8 30 -34 -07 -34 2.9 fn 258-75-34 75 (82) 37 25.8 24 -34 -34 3.9 fn 258-100-35 100 (110) 55 25.8 51 -35 -35 5.5 fn 258-130-35 130 (143) 75 30.0 50 -35 -35 6.9 fn 258-180-.. 180 (197) 90 30.0 73 -40 -07 -40 11.0 fn 258-250-.. 250 (275) 132 30.0 79 -40 -07 -40 12.0 fn 258hv-7-29 7 (7.7) 5.5 13.0 9 -29 -29 1.0 fn 258hv-16-29 16 (17.5) 11 19.0 20 -29 -29 1.5 fn 258hv-30-33 30 (33) 22 19.0 21 -33 -33 1.8 fn 258hv-42-33 42 (46) 30 21.6 30 -33 -33 2.6 fn 258hv-55-34 55 (60) 45 21.6 30 -34 -34 3.0 fn 258hv-75-34 75 (82) 55 21.6 24 -34 -34 4.3 fn 258hv-100-35 100 (110) 90 21.6 51 -35 -35 5.6 fn 258hv-130-35 130 (143) 110 25.0 50 -35 -35 7.1 fn 258hvit-7-29 7 (7.7) 5.5 13.0 9 -29 -29 1.0 fn 258hvit-16-29 16 (17.5) 11 19.0 20 -29 -29 1.5 fn 258hvit-30-33 30 (33) 22 19.0 21 -33 -33 1.8 fn 258hvit-42-33 42 (46) 30 21.6 30 -33 -33 2.6 fn 258hvit-55-34 55 (60) 45 21.6 30 -34 -34 3.0 fn 258hvit-75-34 75 (82) 55 21.6 24 -34 -34 4.3 fn 258hvit-100-35 100 (110) 90 21.6 51 -35 -35 5.6 fn 258hvit-130-35 130 (143) 110 25.0 50 -35 -35 7.1 fn 258l-7-.. 7 (7.7) 4 0.8 9 -29 -07 -29 1.0 fn 258l-16-.. 16 (17.5) 7.5 0.8 20 -29 -07 -29 1.4 fn 258l-30-.. 30 (33) 15 0.8 21 -33 -07 -33 1.7 fn 258l-42-.. 42 (46) 22 0.7 30 -33 -07 -33 2.5 fn 258l-55-.. 55 (60) 30 0.7 30 -34 -07 -34 2.9 fn 258l-75-34 75 (82) 37 0.7 24 -34 -34 3.9 fn 258l-100-35 100 (110) 55 0.7 51 -35 -35 5.5 fn 258l-130-35 130 (143) 75 0.7 50 -35 -35 6.9 fn 258l-180-.. 180 (197) 90 0.7 73 -40 -07 -40 11.0 fn 258l-250-07 250 (275) 132 0.7 79 -40 -07 12.0 fn 258p-7-.. 7 (7.7) 4 3.3 9 -29 -07 -29 1.0 fn 258p-16-.. 16 (17.5) 7.5 3.3 20 -29 -07 -29 1.4 fn 258p-30-.. 30 (33) 15 3.3 21 -33 -07 -33 1.7 fn 258p-42-.. 42 (46) 22 3.5 30 -33 -07 -33 2.5 fn 258p-55-.. 55 (60) 30 3.5 30 -34 -07 -34 2.9 fn 258p-75-34 75 (82) 37 3.5 24 -34 -34 3.9 fn 258p-100-35 100 (110) 55 3.5 51 -35 -35 5.5 fn 258p-130-35 130 (143) 75 3.5 50 -35 -35 6.9 fn 258p-180-.. 180 (197) 90 3.5 73 -40 -07 -40 11.0 fn 258p-250-07 250 (275) 132 3.6 79 -40 -07 12.0 * ** to compile a complete part number, please replace t he -.. with the required output connection style. ** * calculated at rated current, 440 vac (fn 258) / 690 vac (fn 258 hv) and cos phi = 0.8. the exact value depends upon the efficiency of the drive, the moto r and the entire *** application. ***maximum leakage under normal operating condition s (fn 258 at 440 v, fn 258 hv at 690 v). note: if t wo phases are interrupted, worst case leakage could reach 5.7 times *** higher levels. emc/emi products schaffner group datasheets 2014 typical filter attenuation per cispr 17; a = 50 /50 sym; b = 50 /50 asym ; c = 0.1 /100 sym; d = 100 /0.1 sym 7 to 30 a types 42 to 100 a types 130 a types 180 and 250 a types note: typical attenuation performance of fn 258 sta ndard filters. the behavior of fn 258 hv, fn 258hvi t, fn 258p and fn 258l may be slightly different. mechanical data 7 to 55 a types (-07) 7 to 130 a types (-29, -33, -34, -35) 180 and 250 a types (-07) 180 and 250 a types (-40) note: in favour of a better readability, connectors and earth studs are not shown in the horizontal pr ojection. emc/emi products schaffner group datasheets 2014 dimensions 7 a 16 a 30 a 42 a 55 a 75 a 100 a 130 a 180 a 250 a a 255 305 335 329 329 329 379 439 438 478 b 50 55 60 70 80 80 90 110 110 110 c 126 142 150 185 185 220 220 240 240 240 d 225 275 305 300 300 300 350 400 400 440 e 240 290 320 314 314 314 364 414 413 453 f 25 30 35 45 55 55 65 80 80 80 g 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 h 1 1 1 1.5 1.5 1.5 1.5 3 4 4 i 10.9 10.9 25 25 39 39 45 45 51 51 j m5 m5 m5 m6 m6 m6 m10 m10 m10 m10 k 25 27.5 30 35 40 40 45 55 55 55 l 85 100 110 130 105 140 130 140 110 110 x* awg 16 awg 14 awg 10 awg 8 awg 6 50 mm 2 70 mm 2 y* 300 10 300 10 400 10 500 10 500 10 500 10 500 10 z* 9 9 9 12 12 15 15 * filters with output wire connections (-07) only. all dimensions in mm; 1 inch = 25.4 mm tolerances according: iso 2768-m / en 22768-m filter input/output connector cross sections -29 -33 -34 -35 -40 solid wire 6 mm 2 16 mm 2 35 mm 2 50 mm 2 95 mm 2 flex wire 4 mm 2 10 mm 2 25 mm 2 50 mm 2 95 mm 2 awg type wire awg 10 awg 6 awg 2 awg 1/0 awg 4/0 recommended torque 0.6-0.8 nm 1.5-1.8 nm 4.0-4.5 nm 7-8 nm 17-20 nm please visit www.schaffner.com to find more details on filter co nnectors.
4 data sheet 3-phase filters fn 258 book-style emc/rfi filter for inverters and power d rive systems industry standard emc solution for three-phase pds filtering slim space-saving book-style housing solid safety connector blocks or optional wire output connections excellent attenuation performance hv versions for up to 690 vac hvit versions for it distribution networks p/l versions with low leakage current technical specifications design corresponding to ul 1283, csa 22.2 no. 8 1986, iec/en 60939 flammability corresponding to ul 94 v-2 or better high potential test voltage p C> e 2650 vdc for 2 sec (480v filters) p C> p 3000 vdc for 2 sec (690v filters) p C> e 3100 vdc for 2 sec (690v filters) p C> p 2100 vdc for 2 sec (480v filters) information under the labels ul/csa: hv and hvit up to 600 vac maximum continuous operating voltage 3x 480/277 vac (fn 258, fn 258l, fn 258p) 3x 690/400 vac (fn 258hv, fn 258hvit) mtbf @ 50c/400v (mil-hb-217f) 220,000 hours operating frequency dc to 60hz overload capability 4x rated current at switch on, 1.5x rated current for 1 minute, once per hour protection category ip20 rated currents 7 to 250 a @ 50 c (480v filters) temperature range (operation and storage) -25 c to +100 c (25/100/21) approvals ul/csa: fn 258 up to 180 a (ex. -180-07) features and benefits fn 258 range of filters provides state-of- the-art emi attenuation based on an innovative multi-stage filter topology. they help to ensure compliance wit h class a or even class b limits the slim book-style shape allows a convenient and space-saving installation next to inverters and motor drives with 480 vac rating and filter modules from 7 to 250 a, fn 258 are ready for the most diverse applications worldwide fn 258 hv filters up to 130 a are designed for 690 vac distribution networks fn 258hvit filters up to 130 a meet the special requirements for the application in industrial 690 vac it distribution networks fn 258l and fn 258p filters help to fulfill tough requirements in respect of leakage current limitation and provide an excellent solution to overcome problems with nuisance tripping of sensitive earth leakage detectors typical applications three-phase variable speed drives and power drive systems (pds) it power distribution networks (fn 258hvit) applications comprising energy conversion devices (inverters, converters) process automation equipment three-phase power supplies and ups applications with low-leakage current requirements (fn 258l and fn 258p) typical electrical schematic emc/emi products schaffner group datasheets 2014 filter selection table filter* rated current typical drive leakage current *** power loss input output weight @ 50 c (40 c) power rating** @ 440 vac/50 hz @ 25 c/50 hz connections connections [a] [kw] [ma] [w] [kg] fn 258-7-.. 7 (7.7) 4 16.5 9 -29 -07 -29 1.0 fn 258-16-.. 16 (17.5) 7.5 18.3 20 -29 -07 -29 1.4 fn 258-30-.. 30 (33) 15 24.2 21 -33 -07 -33 1.7 fn 258-42-.. 42 (46) 22 25.8 30 -33 -07 -33 2.5 fn 258-55-.. 55 (60) 30 25.8 30 -34 -07 -34 2.9 fn 258-75-34 75 (82) 37 25.8 24 -34 -34 3.9 fn 258-100-35 100 (110) 55 25.8 51 -35 -35 5.5 fn 258-130-35 130 (143) 75 30.0 50 -35 -35 6.9 fn 258-180-.. 180 (197) 90 30.0 73 -40 -07 -40 11.0 fn 258-250-.. 250 (275) 132 30.0 79 -40 -07 -40 12.0 fn 258hv-7-29 7 (7.7) 5.5 13.0 9 -29 -29 1.0 fn 258hv-16-29 16 (17.5) 11 19.0 20 -29 -29 1.5 fn 258hv-30-33 30 (33) 22 19.0 21 -33 -33 1.8 fn 258hv-42-33 42 (46) 30 21.6 30 -33 -33 2.6 fn 258hv-55-34 55 (60) 45 21.6 30 -34 -34 3.0 fn 258hv-75-34 75 (82) 55 21.6 24 -34 -34 4.3 fn 258hv-100-35 100 (110) 90 21.6 51 -35 -35 5.6 fn 258hv-130-35 130 (143) 110 25.0 50 -35 -35 7.1 fn 258hvit-7-29 7 (7.7) 5.5 13.0 9 -29 -29 1.0 fn 258hvit-16-29 16 (17.5) 11 19.0 20 -29 -29 1.5 fn 258hvit-30-33 30 (33) 22 19.0 21 -33 -33 1.8 fn 258hvit-42-33 42 (46) 30 21.6 30 -33 -33 2.6 fn 258hvit-55-34 55 (60) 45 21.6 30 -34 -34 3.0 fn 258hvit-75-34 75 (82) 55 21.6 24 -34 -34 4.3 fn 258hvit-100-35 100 (110) 90 21.6 51 -35 -35 5.6 fn 258hvit-130-35 130 (143) 110 25.0 50 -35 -35 7.1 fn 258l-7-.. 7 (7.7) 4 0.8 9 -29 -07 -29 1.0 fn 258l-16-.. 16 (17.5) 7.5 0.8 20 -29 -07 -29 1.4 fn 258l-30-.. 30 (33) 15 0.8 21 -33 -07 -33 1.7 fn 258l-42-.. 42 (46) 22 0.7 30 -33 -07 -33 2.5 fn 258l-55-.. 55 (60) 30 0.7 30 -34 -07 -34 2.9 fn 258l-75-34 75 (82) 37 0.7 24 -34 -34 3.9 fn 258l-100-35 100 (110) 55 0.7 51 -35 -35 5.5 fn 258l-130-35 130 (143) 75 0.7 50 -35 -35 6.9 fn 258l-180-.. 180 (197) 90 0.7 73 -40 -07 -40 11.0 fn 258l-250-07 250 (275) 132 0.7 79 -40 -07 12.0 fn 258p-7-.. 7 (7.7) 4 3.3 9 -29 -07 -29 1.0 fn 258p-16-.. 16 (17.5) 7.5 3.3 20 -29 -07 -29 1.4 fn 258p-30-.. 30 (33) 15 3.3 21 -33 -07 -33 1.7 fn 258p-42-.. 42 (46) 22 3.5 30 -33 -07 -33 2.5 fn 258p-55-.. 55 (60) 30 3.5 30 -34 -07 -34 2.9 fn 258p-75-34 75 (82) 37 3.5 24 -34 -34 3.9 fn 258p-100-35 100 (110) 55 3.5 51 -35 -35 5.5 fn 258p-130-35 130 (143) 75 3.5 50 -35 -35 6.9 fn 258p-180-.. 180 (197) 90 3.5 73 -40 -07 -40 11.0 fn 258p-250-07 250 (275) 132 3.6 79 -40 -07 12.0 * ** to compile a complete part number, please replace t he -.. with the required output connection style. ** * calculated at rated current, 440 vac (fn 258) / 690 vac (fn 258 hv) and cos phi = 0.8. the exact value depends upon the efficiency of the drive, the moto r and the entire *** application. ***maximum leakage under normal operating condition s (fn 258 at 440 v, fn 258 hv at 690 v). note: if t wo phases are interrupted, worst case leakage could reach 5.7 times *** higher levels. emc/emi products schaffner group datasheets 2014 typical filter attenuation per cispr 17; a = 50 /50 sym; b = 50 /50 asym ; c = 0.1 /100 sym; d = 100 /0.1 sym 7 to 30 a types 42 to 100 a types 130 a types 180 and 250 a types note: typical attenuation performance of fn 258 sta ndard filters. the behavior of fn 258 hv, fn 258hvi t, fn 258p and fn 258l may be slightly different. mechanical data 7 to 55 a types (-07) 7 to 130 a types (-29, -33, -34, -35) 180 and 250 a types (-07) 180 and 250 a types (-40) note: in favour of a better readability, connectors and earth studs are not shown in the horizontal pr ojection. emc/emi products schaffner group datasheets 2014 dimensions 7 a 16 a 30 a 42 a 55 a 75 a 100 a 130 a 180 a 250 a a 255 305 335 329 329 329 379 439 438 478 b 50 55 60 70 80 80 90 110 110 110 c 126 142 150 185 185 220 220 240 240 240 d 225 275 305 300 300 300 350 400 400 440 e 240 290 320 314 314 314 364 414 413 453 f 25 30 35 45 55 55 65 80 80 80 g 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 h 1 1 1 1.5 1.5 1.5 1.5 3 4 4 i 10.9 10.9 25 25 39 39 45 45 51 51 j m5 m5 m5 m6 m6 m6 m10 m10 m10 m10 k 25 27.5 30 35 40 40 45 55 55 55 l 85 100 110 130 105 140 130 140 110 110 x* awg 16 awg 14 awg 10 awg 8 awg 6 50 mm 2 70 mm 2 y* 300 10 300 10 400 10 500 10 500 10 500 10 500 10 z* 9 9 9 12 12 15 15 * filters with output wire connections (-07) only. all dimensions in mm; 1 inch = 25.4 mm tolerances according: iso 2768-m / en 22768-m filter input/output connector cross sections -29 -33 -34 -35 -40 solid wire 6 mm 2 16 mm 2 35 mm 2 50 mm 2 95 mm 2 flex wire 4 mm 2 10 mm 2 25 mm 2 50 mm 2 95 mm 2 awg type wire awg 10 awg 6 awg 2 awg 1/0 awg 4/0 recommended torque 0.6-0.8 nm 1.5-1.8 nm 4.0-4.5 nm 7-8 nm 17-20 nm please visit www.schaffner.com to find more details on filter co nnectors.


▲Up To Search▲   

 
Price & Availability of FN258-7-07

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X